Endometrial Sampling Set 10/box

Integra Miltex

(No reviews yet)
SKU:
MILT30-3015
Availability:
Expected on:04/11/2024
Check Warehouse Availability
Endometrial Sampling Set 10/box

Endometrial Sampling Set (includes Disposable Curette w/a Twist-and-Lock Syringe), Sterile, Single-Use, Box of 10

The Miltex Endometrial Sampling Set is the third product solution to assist Clinicians with the collection of clearly differentiated endometrial tissue. The Endometrial Sampling Set is a disposable plastic curette and syringe system which is very similar in function and appearance to the stainless steel Randall endometrial suction biopsy curette pattern. However, as mentioned previously, the more flexible plastic design reduces physical discomfort to the patient.

Each Miltex Endometrial Sampling Set includes a Disposable Curette and a 10 ml Twist-and-Lock Syringe. The curette is made of clear, latex-free polypropylene and has a Semi-Rigid design with a slightly curved and tapered Randall-type cutting edge tip which optimizes access to the uterine contours and efficient sample collection. The semi-rigid design of the curette allows for controlled insertion in female patients with stenosis of the cervix, and the syringe system creates 21” Hg of negative pressure for optimized suction and sample capture in situations where the endometrium is atrophic and more difficult to capture sufficient sample yield.

Each set is sterilized via ETO, packaged individually for single-use applications, and provided in convenient quantities of 10 per box. The curette is attached to the syringe with the plunger in a closed position and then inserted through the cervix and into the uterine cavity. Once properly positioned, the syringe plunger should be withdrawn in a smooth and steady motion until the piston reaches the safety end stop of the syringe. Turn the plunger ¼ turn clockwise to lock it into position so that sufficient vacuum for maximum endometrial sample yield is captured in the curette sleeve. Detailed “directions for use” are packaged with curette and syringe sampling set and should be reviewed thoroughly and carefully prior to each use or demonstration.


Endometrial Sampling Set

  • 8-1/8" (20.64 cm) length
  • Slight curve on Curette
  • Semi-Rigid Curette with Tapered Tip
  • Randall-Type sharp cutting edge
  • Packaged as a set
  • 10 ml standard Twist-and-Lock Syringe with plunger stop and twist lock.
  • Luer Lock fitting with winged flanges
  • Allows for insertion depth to accommodate a range of patients
  • Optimizes access to the natural uterine contour and structure for obtaining specimens from the endometrial cavity.
  • Ideal for controlled insertion in patients where stenosis or atropic endometrium is a concern.
  • Efficient sample collection.
  • Convenient and ready to use. Comes equipped with a Curette and Twist-and-Lock Syringe.
  • Creates 21" Hg continuous negative pressure for optimized suction and sample capture and prevents the plunger from pulling out of the syringe sheath. Twist lock feature prevents accidental pressurization into the uterus.
  • Better grip and ease of attachment of curette to the syringe