DiaDent Dia-DUO Cordless Warm Vertical Compaction & Backfill Obturation System Regular Kit

(No reviews yet)
SKU:
DIA-4007-2000
Availability:
Estimated 1 Week
Check Warehouse Availability
DiaDent Dia-DUO Cordless Warm Vertical Compaction & Backfill Obturation System Regular Kit
ITEM #4007-2000 Dia-Duo Regular Kit
Contains: Duo-Gun Handpiece, Duo-Pen Handpiece & Duo-Charger,
Heating Condensers #.04-50 and #.06-50, Disposable Sheath (200/box)
GP Obturation Tips (23G, 4/box), Safety Caps (2/pack), Plunger Set,
Plunger O-Ring Assembly (2/pack), Multi-Tool, Scrubbing Brush, Power Adapter, AC Power Cord


Dia-Duo is the new advanced cordless obturation system from DiaDent Group International that consists of both Duo-Gun BackFill Obturation System and Duo-Pen Warm Vertical Compaction System. Dia-Duo is the improved version of Dia-Gun and Dia-Pen and both units can be conveniently charged in the Duo-Charger. Both systems can be fully recharged after 90 minutes.

Duo-Pen Vertical Compaction Device FEATURES:

  • Effectively and tightly compacts and seals all canals including lateral canals
  • Softens, spreads, cuts, and compacts gutta percha
  • Ergonomic design: cordless and lightweight. Easy to hold, clean and store
  • Handpiece remains cool to touch during operation
  • Quick heating tip reaches highest level of temperature within one (1) second to save treatment time
  • Display window on handpiece clearly displays remaining battery power, error and setting temperature
  • Smart temperature control monitors and prevents heating condenser from burning out
  • Duo-Pen handpiece automatically recognizes the size of heating condenser inserted
  • Color-coded heating condensers are available in various sizes
    (#.04-40, .04-45, .04-50, .06-50, .08-55) for easy identification
  • Three temperature settings: 170°C, 200°C, and 230°C
  • Replaceable high energy density lithium-ion battery
  • Simple operation with two buttons: Power/Temperature Button & Operation/Heating Button


Duo-Gun Backfill Obturation System FEATURES:

  • Cordless and compact design allows complete freedom of movement
  • Smooth and precise gutta percha delivery
  • Variable temperature settings (1400C, 1700C, 2000C): precise control of obturation flow
  • Quick and durable heating system: temperature reaches 200°C within 15 seconds
  • Fast and continuous flow of gutta percha filling tightly seals the canal
  • Designed for both left-handed and right-handed individuals:
    Both sides of the handpiece have power button and display window
    Both display windows show the remaining battery power, error and setting temperature
  • Sophisticated and ergonomic design: operate hand trigger obturation with minimal effort
  • Smart temperature control system maintains stable and constant temperature during operation
  • Replaceable high energy density lithium-ion battery
  • Strong, durable, and bendable Duo-Gun tips are available in both 23G and 25G

DOWNPACK OBTURATION:

1a. Shape the root canal with endo files and determine the working length. Select a master cone that closely matches the apical size.

1b. Insert Duo-Pen tip (heating condenser)into the root canal to the point 4-7 mm short of the working length. Move and set the endo stop accordingly.

2. Insert the selected master Gutta Percha cone that is coated with sealer.

3a. Place the Duo-Pen tip in the orifice of the canal and activate Duo-Pen by pressing the Operation Button. Using the activated tip, cut the middle of gutta percha cone and condense the soften material to the point 6-9 mm front the apex for about 2 seconds.

3b. Release the Operation Button to allow pen tip to cool down, while at the same time continue pushing and holding the cooled pen tip to the apex for 8 seconds. This ensures all lateral and accessory canals are filled. Activate the pen tip again by pressing and holding the Operation Button for about 1~1.5 seconds, compact the gutta percha cone to the point 4~7 mm of working length.

4. Condense the remaining material using Dia-Kondensor.

BACKFILL OBTURATION:

5a. Insert a gutta percha pellet into Duo-Gun and adjust to the desired preset temperature.

5b. Using Duo-Gun’s activated tip, make contact with the upper part of filled master cone in the canal, transfer heat for 3-5 seconds to soften the material.

6a. Extrude the melted gutta percha obturator into the canal.

6b. Continue flowing while withdrawing the tip from the canal.

7. Use Dia-Kondensor to compact obturation material.

EvoFill Backfill


Please note that EvoPack's Heating Condenser and Duo-Pen Tips are not interchangeable.