Key Features & Benefits
- Stronger Hold Adhesion: Formulated with an upgraded, aggressive conductive adhesive compared to standard tab electrodes (such as the 2330), ensuring secure skin contact—even on challenging skin surfaces.
- Instant Signal Quality: Continuous conductive adhesive gel delivers immediate skin contact for clear, reliable EKG trace collection without signal delay.
- Radiolucent Design: Minimizes artifact interference and eliminates the need to remove or replace electrodes during X-rays or radiological imaging procedures.
- Repositionable & Clean Removal: Allows for effortless placement adjustments during prep while leaving little to no sticky adhesive residue on the patient’s skin upon removal.
- Defibrillation-Proof: Maintains conductivity and signal stability even after defibrillation events.
- Not Made with Natural Rubber Latex: Safe for latex-sensitive patients and clinical staff.
Product Overview
The 3M™ Red Dot™ Resting EKG Electrode 2360 (Solventum™) delivers high-performance signal accuracy for diagnostic resting 12-lead EKGs and echocardiograms. Designed specifically for short-term cardiac diagnostics, the 2360 series features a stronger, pressure-sensitive conductive adhesive gel that ensures immediate intimate skin contact without slipping or lifting.
The tab-style connector makes lead-wire attachment fast and convenient for clinicians while maintaining a low profile. Built with a flexible backing to prevent roll-off, these diagnostic electrodes offer effortless repositioning during setup and peel away cleanly without damaging normal skin or leaving adhesive transfer.
Technical Specifications
|
Specification |
Details |
|
Catalog Number |
2360 |
|
Electrode Type |
Resting EKG / ECG Tab Style |
|
Dimensions |
0.79 in x 0.79 in (2 cm x 2 cm) |
|
Gel / Adhesive Type |
Conductive Gel / Pressure-Sensitive Adhesive |
|
Radiolucency |
Radiolucent |
|
Skin Type Compatibility |
Normal Skin |
|
Age Group |
Adult |
|
Backing Material |
Plastic Film |
|
Latex Indicator |
Not made with natural rubber latex |
Frequently Asked Questions (FAQs)
What is the difference between the 3M 2330 and 3M 2360 EKG electrodes?
The 3M Red Dot 2360 features a stronger, more aggressive adhesive designed for situations requiring superior adhesion compared to the 3M 2330, which is formulated for more gentle or fragile skin applications.
Are 3M 2360 electrodes radiolucent?
Yes. The 2360 series electrodes are radiolucent, meaning they do not interfere with standard diagnostic radiological imaging or X-rays and do not need to be removed prior to imaging.
Can these electrodes be repositioned after initial application?
Yes, the pressure-sensitive adhesive allows clinicians to adjust placement during patient setup without losing stickiness or leaving excessive residue.