Key Features & Benefits
- Gentle Yet Secure Adhesion: Specially formulated adhesive designed for both fragile and normal skin, preventing trauma or tearing during removal while ensuring reliable contact.
- Rapid Signal Trace Quality: Conductive adhesive gel offers instant skin contact for fast, clear, and consistent diagnostic EKG trace acquisition.
- Radiolucent Construction: Eliminates image interference on X-rays and radiological scans, saving clinical time by removing the need to strip and replace electrodes.
- Repositionable Design: Allows clinicians to easily adjust tab placement during setup without losing adhesive strength.
- Defibrillation-Proof: Maintains electrical conductivity and signal integrity following defibrillation procedures.
- Latex-Free Safety: Not made with natural rubber latex, protecting latex-sensitive patients and healthcare personnel.
Product Overview
The Solventum™ Red Dot™ Resting EKG Electrode 2330 (formerly 3M™ Red Dot™ 2330) provides accurate diagnostic performance for 12-lead resting EKGs and echocardiograms. Specifically engineered for short-term diagnostic procedures, the 2330 series balances continuous conductivity with a gentle pressure-sensitive adhesive.
Unlike stronger adhesives that can compromise delicate tissue, the 2330 electrode is optimized for patients with fragile, sensitive, or normal skin. The tab-style profile allows lead wires to clip on securely while staying flat against the patient, and the flexible backing resists curling to maintain stable skin contact throughout testing.
Technical Specifications
|
Specification |
Details |
|
Catalog Number |
2330 |
|
Electrode Type |
Resting EKG / ECG Tab Style |
|
Dimensions |
0.79 in x 0.79 in (2 cm x 2 cm) |
|
Adhesive / Gel Type |
Conductive Gel / Pressure-Sensitive Adhesive |
|
Radiolucency |
Radiolucent |
|
Skin Type Compatibility |
Fragile Skin & Normal Skin |
|
Age Group |
Adult |
|
Monitoring Event |
Echo-Cardio / Resting EKG |
|
Latex Indicator |
Not made with natural rubber latex |
Frequently Asked Questions (FAQs)
What is the difference between Solventum Red Dot 2330 and 2360 electrodes?
The 2330 model is designed with a gentle adhesive suitable for sensitive or fragile skin, whereas the 2360 model features a stronger, higher-tack adhesive for applications requiring enhanced hold on challenging skin.
Is the 3M 2330 EKG electrode transitioning to Solventum?
Yes. 3M Health Care is transitioning its medical products to Solventum™. The Solventum™ Red Dot™ 2330 delivers the same trusted performance and specs as the original 3M Red Dot 2330.
Can 2330 tab electrodes be left on during X-rays?
Yes. The 2330 series electrodes are radiolucent, meaning they will not cause shadows or interference on radiological images or X-rays and do not need to be removed prior to imaging.